Review



bio rad tumor marker controls level 1 level 2 level 3  (Bio-Rad)


Bioz Verified Symbol Bio-Rad is a verified supplier
Bioz Manufacturer Symbol Bio-Rad manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 93

    Structured Review

    Bio-Rad bio rad tumor marker controls level 1 level 2 level 3
    Bio Rad Tumor Marker Controls Level 1 Level 2 Level 3, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 151 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/bio+rad+tumor+marker+controls+level+1+level+2+level+3/Lyphochek+Therapeutic+Drug+Monitoring+Control+(TDM)/us11953507-445-83-83
    Average 93 stars, based on 151 article reviews
    bio rad tumor marker controls level 1 level 2 level 3 - by Bioz Stars, 2026-11
    93/100 stars

    Images

    Related Articles

    Intra Assay:

    Article Title: Quantitation of insulin-like growth factor-I and insulin-like growth factor-II with high-resolution mass spectrometry
    Article Snippet: Data from these analyses are presented in Table 2 (for in-house QC pools) and Table 3 (for Bio-Rad Tumor Marker Controls). .. TABLE 2 Intact IGF-I Intra-Assay Variation using In-House QC Pools QC 1 QC 2 QC 3 Replicate (100 ng/mL) (400 ng/mL) (741 ng/mL) 1 96.0 385.6 746.7 2 105.5 407.9 735.5 3 109.5 403.5 774.2 4 98.5 396.7 779.7 5 108.1 399.4 776.6 6 105.7 389.0 754.7 7 104.3 405.0 775.7 8 98.4 410.2 756.3 9 99.9 386.8 752.7 10 102.0 395.3 729.4 Mean 102.8 397.9 758.2 SD 4.51 8.81 17.89 % CV 4.4 2.2 2.4 TABLE 3 Intact IGF-I Intra-Assay Variation using Bio-Rad Tumor Marker Controls Level 1 Level 2 Level 3 (Lot 19851) (Lot 19852) (Lot 19853) Replicate (ng/mL) (ng/mL) (ng/mL) 1 57.8 245.8 444.2 2 55.5 243.2 431.7 3 55.0 248.5 435.4 4 57.5 248.7 451.1 5 56.1 245.6 452.7 6 58.6 248.3 451.3 7 58.5 247.3 429.7 8 58.0 234.2 446.6 9 56.6 241.9 445.5 10 56.9 244.4 442.7 Mean 57.1 244.8 443.1 SD 1.23 4.37 8.25 % CV 2.2 1.8 1.9 Statistics performed on the results of quantitation demonstrated that the reproducibility (CV) for the six QC pools ranged from 2.4% to 4.4% for spiked in-house QC pools and from 1.8% to 2.2% for Bio-Rad Tumor Marker Controls. ..

    Marker:

    Article Title: Quantitation of insulin-like growth factor-I and insulin-like growth factor-II with high-resolution mass spectrometry
    Article Snippet: Data from these analyses are presented in Table 2 (for in-house QC pools) and Table 3 (for Bio-Rad Tumor Marker Controls). .. TABLE 2 Intact IGF-I Intra-Assay Variation using In-House QC Pools QC 1 QC 2 QC 3 Replicate (100 ng/mL) (400 ng/mL) (741 ng/mL) 1 96.0 385.6 746.7 2 105.5 407.9 735.5 3 109.5 403.5 774.2 4 98.5 396.7 779.7 5 108.1 399.4 776.6 6 105.7 389.0 754.7 7 104.3 405.0 775.7 8 98.4 410.2 756.3 9 99.9 386.8 752.7 10 102.0 395.3 729.4 Mean 102.8 397.9 758.2 SD 4.51 8.81 17.89 % CV 4.4 2.2 2.4 TABLE 3 Intact IGF-I Intra-Assay Variation using Bio-Rad Tumor Marker Controls Level 1 Level 2 Level 3 (Lot 19851) (Lot 19852) (Lot 19853) Replicate (ng/mL) (ng/mL) (ng/mL) 1 57.8 245.8 444.2 2 55.5 243.2 431.7 3 55.0 248.5 435.4 4 57.5 248.7 451.1 5 56.1 245.6 452.7 6 58.6 248.3 451.3 7 58.5 247.3 429.7 8 58.0 234.2 446.6 9 56.6 241.9 445.5 10 56.9 244.4 442.7 Mean 57.1 244.8 443.1 SD 1.23 4.37 8.25 % CV 2.2 1.8 1.9 Statistics performed on the results of quantitation demonstrated that the reproducibility (CV) for the six QC pools ranged from 2.4% to 4.4% for spiked in-house QC pools and from 1.8% to 2.2% for Bio-Rad Tumor Marker Controls. ..

    Quantitation Assay:

    Article Title: Quantitation of insulin-like growth factor-I and insulin-like growth factor-II with high-resolution mass spectrometry
    Article Snippet: Data from these analyses are presented in Table 2 (for in-house QC pools) and Table 3 (for Bio-Rad Tumor Marker Controls). .. TABLE 2 Intact IGF-I Intra-Assay Variation using In-House QC Pools QC 1 QC 2 QC 3 Replicate (100 ng/mL) (400 ng/mL) (741 ng/mL) 1 96.0 385.6 746.7 2 105.5 407.9 735.5 3 109.5 403.5 774.2 4 98.5 396.7 779.7 5 108.1 399.4 776.6 6 105.7 389.0 754.7 7 104.3 405.0 775.7 8 98.4 410.2 756.3 9 99.9 386.8 752.7 10 102.0 395.3 729.4 Mean 102.8 397.9 758.2 SD 4.51 8.81 17.89 % CV 4.4 2.2 2.4 TABLE 3 Intact IGF-I Intra-Assay Variation using Bio-Rad Tumor Marker Controls Level 1 Level 2 Level 3 (Lot 19851) (Lot 19852) (Lot 19853) Replicate (ng/mL) (ng/mL) (ng/mL) 1 57.8 245.8 444.2 2 55.5 243.2 431.7 3 55.0 248.5 435.4 4 57.5 248.7 451.1 5 56.1 245.6 452.7 6 58.6 248.3 451.3 7 58.5 247.3 429.7 8 58.0 234.2 446.6 9 56.6 241.9 445.5 10 56.9 244.4 442.7 Mean 57.1 244.8 443.1 SD 1.23 4.37 8.25 % CV 2.2 1.8 1.9 Statistics performed on the results of quantitation demonstrated that the reproducibility (CV) for the six QC pools ranged from 2.4% to 4.4% for spiked in-house QC pools and from 1.8% to 2.2% for Bio-Rad Tumor Marker Controls. ..



    Similar Products

    93
    Bio-Rad bio rad tumor marker controls level 1 level 2 level 3
    Bio Rad Tumor Marker Controls Level 1 Level 2 Level 3, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/bio+rad+tumor+marker+controls+level+1+level+2+level+3/Lyphochek+Therapeutic+Drug+Monitoring+Control+(TDM)/us11953507-445-83-83
    Average 93 stars, based on 1 article reviews
    bio rad tumor marker controls level 1 level 2 level 3 - by Bioz Stars, 2026-11
    93/100 stars
      Buy from Supplier

    Image Search Results